Skip to main content
Services

UST & AST Petroleum Compliance Testing

Explore PTTI’s testing services and request a quote for the equipment and requirements at your site.

Credentials and memberships
Estabrook
Four categories

Nine services, four categories.

1

Tank & Line Compliance Testing

Tank tightness, volumetric line tightness, and line leak detector testing for petroleum systems.

Tank Tightness Testing · Line Tightness Testing · Leak Detector Testing

2

Detection & Verification

ATG functionality testing and diagnostic helium leak detection after a confirmed failure.

ATG Functionality Testing · Helium Leak Detection

3

Containment & Overfill Testing

Spill bucket, containment sump, and overfill-prevention testing for the equipment installed at your site.

Spill Bucket Testing · Containment Sump Testing · Overfill Prevention Testing

4

Air Quality Testing

Air quality testing for petroleum systems. State requirements vary.

Air Quality Testing

Per-state variation

Each state runs its own compliance calendar.

Serving 13 states and expanding. Testing requirements vary by site and jurisdiction.

We track the forms, deadlines, and inspector preferences for your specific state and site. Ask us what applies where you operate.

Category 1
1

Tank & Line Compliance Testing

Tank tightness, volumetric line tightness, and line leak detector testing for petroleum systems.

1.1

Tank Tightness Testing

Non-volumetric testing with the Estabrook EZY 3 Locator Plus and volumetric interstitial testing with Xerxes Truchek for compatible double-wall systems.

40 CFR 280.43(c)

See details →
1.2

Line Tightness Testing

Volumetric testing for pressurized, suction, and gravity-fed product lines.

40 CFR 280.41 and 280.44

See details →
1.3

Leak Detector Testing

Functionality testing for mechanical and electronic line leak detectors.

40 CFR 280.40 and 280.44(a)

See details →
Category 2
2

Detection & Verification

ATG functionality testing and diagnostic helium leak detection after a confirmed failure.

2.1

ATG Functionality Testing

Functionality testing for automatic tank gauges, probes, sensors, and alarms.

40 CFR 280.40

See details →
2.2

Helium Leak Detection

Pinpoint leak location after a failure has been confirmed with positive isolation.

Diagnostic, post-failure localization

See details →
Category 3
3

Containment & Overfill Testing

Spill bucket, containment sump, and overfill-prevention testing for the equipment installed at your site.

3.1

Spill Bucket Testing

Hydrostatic or vacuum testing for compatible spill-containment equipment.

40 CFR 280.35

See details →
3.2

Containment Sump Testing

Hydrostatic and Dri-Sump testing for containment sumps, with the method selected for the site.

40 CFR 280.35

See details →
3.3

Overfill Prevention Testing

Testing of the overfill-prevention devices installed at your site.

40 CFR 280.35 and 280.20(c)

See details →
Category 4
4

Air Quality Testing

Air quality testing for petroleum systems. State requirements vary.

4.1

Air Quality Testing

Air quality testing for petroleum systems. State requirements vary.

Applicable federal, state, and local air-quality requirements

See details →
Selected work

Compliance programs across the industries we serve.

Fleet operator

Regional fleet network

ATG functionality verification plus air quality testing per state schedule across fleet depot yards in the Mountain West.

Hospital

Hospital generator network

Annual compliance package across medical facilities in Utah and Colorado: tank tightness, line tightness, spill bucket, containment sump. Continuous multi-year coverage.

Government and defense

Agency fuel infrastructure

Triennial compliance bundling across government fuel sites: spill bucket, containment sump, overfill, line tightness. Multi-year contract relationship.

Get a quote

Every required test. One crew. One visit.

Explore PTTI’s petroleum-system testing and diagnostic services. Tell us about your site and testing requirements.

Call (801) 886-9224 Get a quote